Issue 11, 2015

High-precision barium isotope measurements by MC-ICP-MS

Abstract

We present a high precision method to measure Ba isotopes by multiple-collector inductively coupled plasma-mass spectrometry (MC-ICP-MS). Barium is separated from matrices by using a cation exchange resin (AG50W-X12, 200–400 mesh). Instrumental mass bias of Ba isotopes was corrected by a sample-standard bracketing method using SRM3104a as the bracketing standard. Potential effects of different matrices from resin and samples, and acid molarity and concentration mismatch were rigorously evaluated in this study. The precision and accuracy of this method were tested by the measurement of a synthetic solution made by mixing SRM3104a Ba with other matrix elements. The average δ137/134Ba of the synthetic solution is −0.005 ± 0.047‰ (2SD, n = 36) relative to SRM3104a. The robustness of this method was further assessed by replicated analyses of 8 reference materials, including igneous rocks with mafic to felsic compositions. The δ137/134Ba of basalt standards BCR-2, BHVO-2, and JB-2 is 0.050 ± 0.039‰ (2SD, n = 13), 0.047 ± 0.028‰ (2SD, n = 22), and 0.085 ± 0.035‰ (2SD, n = 19), respectively; diabase standard W-2 is 0.035 ± 0.022‰ (2SD, n = 11); andesite standard AGV-1 is 0.047 ± 0.040‰ (2SD, n = 11) and JA-2 is 0.038 ± 0.048‰ (2SD, n = 17); rhyolite standard RGM-1 is 0.142 ± 0.030‰ (2SD, n = 15); and granodiorite standard GSP-2 is 0.013 ± 0.046‰ (2SD, n = 15). Two late Mesozoic basalts from China have a δ137/134Ba of −0.132 ± 0.020‰ (2SD, n = 7) and 0.001 ± 0.034‰ (2SD, n = 7), respectively. Based on repeated analyses of the synthetic standard and a carbonate standard IAEA-CO-9, the long-term external precision of our method is better than ±0.05‰, much smaller than the variation of δ137/134Ba in these reference standards and samples (up to 0.27‰). Therefore, the Ba isotopic composition can be used as a novel tracer to study geochemical processes.

Graphical abstract: High-precision barium isotope measurements by MC-ICP-MS

Article information

Article type
Paper
Submitted
03 May 2015
Accepted
25 Aug 2015
First published
25 Aug 2015

J. Anal. At. Spectrom., 2015,30, 2307-2315

Author version available

High-precision barium isotope measurements by MC-ICP-MS

X. Nan, F. Wu, Z. Zhang, Z. Hou, F. Huang and H. Yu, J. Anal. At. Spectrom., 2015, 30, 2307 DOI: 10.1039/C5JA00166H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements