Effects of mercury and thallium concentrations on high precision determination of mercury isotopic composition by Neptune Plus multiple collector inductively coupled plasma mass spectrometry

Abstract

Thallium (Tl) has been widely used as an internal standard for mass bias correction during high precision mercury (Hg) isotope ratio measurements using multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). However, a recent study by Georg and Newman indicated the potential for Hg hydride formation (HgHx, x = 1, 2) during Hg isotope measurements using an X skimmer cone with a Neptune Plus MC-ICP-MS. Mercury hydride formation could result in an artificial change in 205Tl/203Tl. Due to this observation, the applicability of using Tl as an internal standard for instrumental mass bias correction during high precision Hg isotope measurements has been questioned. In this study, using an adapted gas/liquid phase separator for Hg introduction and the NIST SRM 997 Tl standard for mass bias correction, mercury isotope measurements were performed using a Neptune Plus MC-ICP-MS. While we confirm Georg and Newman's observations, we show that Hg hydride formation is less important when Hg isotope measurements are conducted with high Tl and low Hg concentrations. With careful sample-standard bracketing (with Hg concentration matching within 10%), we demonstrate that measuring 20 to 50 ng mL−1 of Tl and 0.5 to 3.0 ng mL−1 of Hg, high precision Hg isotope ratio measurements are achievable. We caution researchers using other Hg inlet systems to recognize the importance of Hg and Tl concentrations and encourage the optimization of these values during their Hg isotope measurements.

Graphical abstract: Effects of mercury and thallium concentrations on high precision determination of mercury isotopic composition by Neptune Plus multiple collector inductively coupled plasma mass spectrometry

Supplementary files

Article information

Article type
Paper
Submitted
21 Mar 2016
Accepted
02 Sep 2016
First published
02 Sep 2016

J. Anal. At. Spectrom., 2016,31, 2060-2068

Author version available

Effects of mercury and thallium concentrations on high precision determination of mercury isotopic composition by Neptune Plus multiple collector inductively coupled plasma mass spectrometry

R. Yin, D. P. Krabbenhoft, B. A. Bergquist, W. Zheng, R. F. Lepak and J. P. Hurley, J. Anal. At. Spectrom., 2016, 31, 2060 DOI: 10.1039/C6JA00107F

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements