Issue 7, 2024

Interaction of the III-As monolayer with SARS-CoV-2 biomarkers: implications for biosensor development

Abstract

The emergence of SARS-CoV-2 in 2019 led to the global COVID-19 pandemic, highlighting the urgency for developing cost-effective and non-invasive methods to detect diseases at an early stage. Human breath, rich in volatile organic compounds (VOCs), is promising for cost-effective and rapid disease detection, with specific VOCs like methanol, ethanal, butanone, acetone, and ethyl butyrate linked to COVID-19. Recent advances in biomarker detection and gas sensing with 2D materials, particularly III-As monolayers like BAs, GaAs, and AlAs, offer high sensitivity at low concentrations, providing a novel avenue for exploring their potential in detecting COVID-19 biomarkers. This article aims to examine the effects of adsorption on different properties of III-Arsenide (BAs, GaAs and AlAs) monolayers, particularly in connection with SARS-CoV-2 biomarkers. In order to examine the interaction between the monolayers and biomarkers, first-principles computations within the framework of density functional theory (DFT) are utilized. The present study involves an investigation of the modifications in the band structure, density of states (DOS), work function, electron density difference, and optical properties (reflectance and absorbance) of III-As monolayers, with the aim of assessing their viability for the detection of SARS-CoV-2 biomarkers along with interfering gases such as CO2 and H2O. It is observed that VOCs induce a notable change in the work function of GaAs which serves as an indicator of the presence of these biomarkers. However, the changes in work function are not as substantial as those for AlAs and BAs. Additionally, the chemiresistive sensitivity, optical sensitivity and recovery time of III-As are investigated. The findings suggest that the pristine GaAs monolayer displays a significant level of sensitivity and selectivity towards the SARS-CoV-2 biomarkers, rendering it a material with potential for utilization in sensing applications. Furthermore, it has been observed that the recovery time of the GaAs monolayer subsequent to its exposure to the VOC biomarkers lies within an acceptable threshold. Upon exposure to UV light, the recovery time is further reduced. The outcomes of our study indicate that GaAs monolayers exhibit considerable potential as chemiresistive, work function-based and optical sensors for the precise and discerning identification of VOCs linked to the SARS-CoV-2 virus compared to the other two III-As monolayers.

Graphical abstract: Interaction of the III-As monolayer with SARS-CoV-2 biomarkers: implications for biosensor development

Supplementary files

Article information

Article type
Paper
Submitted
27 Oct 2023
Accepted
22 Jan 2024
First published
25 Jan 2024

Phys. Chem. Chem. Phys., 2024,26, 6242-6255

Interaction of the III-As monolayer with SARS-CoV-2 biomarkers: implications for biosensor development

S. Saha, D. I. Sajib and Md. K. Alam, Phys. Chem. Chem. Phys., 2024, 26, 6242 DOI: 10.1039/D3CP05215J

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements