Building characterization and aerosol infiltration into a naturally ventilated three-story apartment building

Abstract

Understanding infiltration of outdoor pollutants was an integral part of the Brooklyn Traffic Real-Time Ambient Pollutant Penetration and Environmental Dispersion (B-TRAPPED) study. For this reason, the structural and air exchange properties of the three-story row house in Brooklyn, NY, USA, that was used in the B-TRAPPED experiments were fully characterized. Factors investigated included representativeness of the construction and impact of building design features on the natural ventilation and infiltration of outdoor aerosol. Both blower door and perfluorocarbon tracer (PFT) air exchange rate (AER) experiments showed that the ventilation rates of the building were quite typical of similar structures in the New York City (NYC) metropolitan area. Indoor/outdoor (I/O) aerosol count ratios by particle size were comparable to a similar vintage naturally ventilated building in Boston, MA, USA. I/O ratio analyses were consistent with literature findings and showed I/O ratios ranging from 0.310 to 0.601, varying across particle sizes (from 0.3 to 0.5 μm) and between first and second floor apartments. An effort to apply the rebound method of Thatcher et al. (Aerosol Sci. Technol., 2003, 37, 847–864) in determining aerosol infiltration rates proved unsuccessful due to unexpectedly long (>60 min) equilibration times after the filtration period. Uninsulated interior wall renovations in the study house created a cavity that resulted in a large intermediate dead volume (for infiltration) that apparently could not be accommodated by a simple infiltration model. Simple two-compartment models evidently have finite application limitations for even modestly complex settings.

Graphical abstract: Building characterization and aerosol infiltration into a naturally ventilated three-story apartment building

Supplementary files

Additions and corrections

Article information

Article type
Paper
Submitted
07 Apr 2009
Accepted
28 Sep 2009
First published
06 Nov 2009

J. Environ. Monit., 2009,11, 2180-2191

Building characterization and aerosol infiltration into a naturally ventilated three-story apartment building

C. E. Rodes, D. W. VanOsdell, J. W. Portzer, J. Seagraves, I. Hahn, S. W. Henkle and R. W. Wiener, J. Environ. Monit., 2009, 11, 2180 DOI: 10.1039/B907139N

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Spotlight

Advertisements