Precise measurement of stable neodymium isotopes of geological materials by using MC-ICP-MS

Abstract

A method has been developed to determine high-precision stable Nd isotopic compositions in geological samples by multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) using sample-standard-bracketing (SSB) mode. Nd was pre-concentrated and purified through a two-column ion-exchange chromatographic procedure. The recovery for Nd is generally better than 96%, and the interferences, such as Ce and Sm can be efficiently removed, allowing negligible influence on the stable Nd isotopic composition during mass spectrometry measurement. The internal precision for the stable Nd isotopic compositions, ε142Nd, ε145Nd, ε146Nd and ε148Nd were generally better than ±0.2 (2 SEM), and the external precision was generally better than ±0.2 (1 SD) for ε142Nd, ε145Nd and ε146Nd, and better than ±0.5 (1 SD) for ε148Nd based on the long-term results of the Nd standard solutions, such as La Jolla, Nd-GIG and NIST 3135a. Both the internal and external precisions are comparable to those by double-spike method. The averages of our measured ε142Nd, ε145Nd, ε146Nd and ε148Nd results of La Jolla are identical to those by the double-spike method within analytical error. Thus, our method can provide comparable results with the double-spike method, but does not bring any inconvenience of calibrating double spikes, and the efficiency is greatly improved. This provides a more convenient way for studying stable Nd isotopes in geological processes. By using this method, the stable Nd isotopic compositions for a series of international rock standard references were measured.

Graphical abstract: Precise measurement of stable neodymium isotopes of geological materials by using MC-ICP-MS

Article information

Article type
Technical Note
Submitted
10 Jul 2013
Accepted
07 Oct 2013
First published
08 Oct 2013

J. Anal. At. Spectrom., 2013,28, 1926-1931

Precise measurement of stable neodymium isotopes of geological materials by using MC-ICP-MS

J. Ma, G. Wei, Y. Liu, Z. Ren, Y. Xu and Y. Yang, J. Anal. At. Spectrom., 2013, 28, 1926 DOI: 10.1039/C3JA50229E

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements