Optical surrogates (i.e., absorbance and fluorescence) are of interest to monitor drinking water treatment processes due to their potential for implementation as online sensors. This study compares the use of different optical surrogates to model dissolved organic carbon (DOC) removal by coagulation with aluminum sulfate in the dose range of 5 to 120 mg L−1 in 22 source waters with a wide range of water qualities (specific UV absorbance (SUVA254) – 1.0 to 4.0 L mgC−1 m−1). Linear regressions were developed relating percent DOC removal to percent fluorescence decrease at discrete wavelength pairs in an excitation-emission matrix (2029 wavelength pairings). DOC removal was modeled with an average 95% prediction interval between 10.5–15% at all emission wavelengths greater than 375 nm, suggesting that wavelength selection for use in fluorescence monitoring is relatively unimportant. Fluorescence data without inner filter corrections led to a decrease in model performance, but prediction intervals were still between 12–15% at emission wavelengths greater than 400 nm. By comparison, the average prediction interval for an analogous model with UV absorbance at 254 nm was 10.5% (DOCr% = 0.7 UVr%, R2 = 0.91), performing the same as the best possible fluorescence wavelength combinations. Additional modeling found that tracking multiple optical surrogates in tandem does not improve model performance due to correlated independent variables. Raw water optical properties (SUVA254 and fluorescence ratios) modeled DOC removal at a single coagulant dose (~40 mg L−1), but fluorescence indicators did not significantly outperform SUVA254. A PARAFAC model built with 112 fluorescence samples with six validated components demonstrated the range of fluorescence behaviors in the dataset and guided the selection of fluorescence ratios to predict removal based on raw water characteristics. These results demonstrated that fluorescence wavelength is relatively unimportant for online monitoring approaches that measure both raw and clarified samples, but emission wavelength is a driving factor for predicting removal based solely on raw water characteristics.

Graphical abstract: Evaluation of optical surrogates for the characterization of DOM removal by coagulation

Supplementary files

Article information

Article type
Paper
Submitted
29 Jan 2015
Accepted
18 May 2015
First published
19 May 2015

Environ. Sci.: Water Res. Technol., 2015,1, 493-506

Evaluation of optical surrogates for the characterization of DOM removal by coagulation

J. A. Korak, F. L. Rosario-Ortiz and R. Scott Summers, Environ. Sci.: Water Res. Technol., 2015, 1, 493 DOI: 10.1039/C5EW00024F

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements