Separation of Mg, Ca and Fe from geological reference materials for stable isotope ratio analyses by MC-ICP-MS and double-spike TIMS

Abstract

Near quantitative separation of analyte elements from the sample matrix is commonly required to obtain precise and accurate stable isotope data, especially if MC-ICP-MS is used in conjunction with the standard-sample bracketing (SSB) technique for mass bias drift correction. Here, we report a robust procedure that allows for the combined chemical separation of Mg, Ca and Fe, using ion-exchange columns that contain 1 ml AG50W-X8 (200–400 mesh) cation exchange resin. Magnesium was separated for isotope ratio analyses from many geological sample types by a single pass through this column. For Mg purification, Be, Ti, Mn, Fe and Al are selectively eluted using dilute HF and an acetone–HCl mixture. The separation of Mg from Ca-dominated carbonate samples and/or a combination of Mg, Ca and Fe separation from the same sample aliquot, is achieved by the adsorption of Ca and Fe onto the ion-exchange resin from 10 M HCl. Following purification, geological reference materials, including water, bone, carbonate and sediment samples, igneous and sedimentary rocks and a chondritic meteorite were analysed by MC-ICP-MS (Mg and Fe isotopes) and double-spike TIMS (Ca isotopes). Average external repeatabilities were ±0.16‰ for 26Mg/24Mg, ±0.26‰ for 44Ca/40Ca and ±0.05‰ for 56Fe/54Fe (2sd; n ≥ 5). Comparison with published data documents the accuracy of the results. For Mg isotope analyses using SSB-MC-ICP-MS, matrix-induced mass bias effects were studied using element additions. The artificial matrices left a memory in subsequent standard analyses, likely due to depositions on the cones. This observation allowed for the detection of matrix effects in unknown samples. Finally, the current status of Mg and Ca zero-delta reference materials is briefly discussed.

Graphical abstract: Separation of Mg, Ca and Fe from geological reference materials for stable isotope ratio analyses by MC-ICP-MS and double-spike TIMS

Article information

Article type
Paper
Submitted
12 Nov 2008
Accepted
05 Feb 2009
First published
27 Feb 2009

J. Anal. At. Spectrom., 2009,24, 627-636

Separation of Mg, Ca and Fe from geological reference materials for stable isotope ratio analyses by MC-ICP-MS and double-spike TIMS

F. Wombacher, A. Eisenhauer, A. Heuser and S. Weyer, J. Anal. At. Spectrom., 2009, 24, 627 DOI: 10.1039/B820154D

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements