On-line, real time monitoring of exhaled trace gases by SIFT-MS in the perioperative setting: a feasibility study

Abstract

A study is described of the first on line, real time analyses of the exhaled breath of five anaesthetized patients during the complete perioperative periods of laparoscopic surgery. These breath analyses were achieved using a selected ion flow tube, SIFT-MS, instrument, located in the operating theatre at an acceptable distance from the operating table, and coupled to the endotracheal tube in the ventilation circuit via a 5 metre long capillary tube. Thus, inhalation/exhalation breathing cycles, set to be at a frequency of 10 per minute, were sampled continuously for water vapour, the metabolites acetone and isoprene and the propofol used to induce anaesthesia for each operating period that ranged from 20 min (shortest) to 80 min (longest). Whilst there was some loss of water vapour along the long sampling line, the concentrations of the other trace compounds were not diminished. The breath acetone was essentially at a constant level for each patient, but increased somewhat over the longest operating period due to the onset of lipolysis. Most interesting is the clear increase of breath isoprene following abdomen inflation with carbon dioxide. The vapour of the intravenously injected propofol was detected in the exhaled breath and remained essentially constant during the perioperative period. These analyses were performed totally non-invasively and the data were immediately and constantly available to the anaesthetist and surgeon. Exploitation of this development could influence decision making and potentially improve patient safety within the perioperative setting.

Graphical abstract: On-line, real time monitoring of exhaled trace gases by SIFT-MS in the perioperative setting: a feasibility study

Article information

Article type
Communication
Submitted
27 Apr 2011
Accepted
06 Jun 2011
First published
30 Jun 2011

Analyst, 2011,136, 3233-3237

On-line, real time monitoring of exhaled trace gases by SIFT-MS in the perioperative setting: a feasibility study

P. R. Boshier, J. R. Cushnir, V. Mistry, A. Knaggs, P. Španěl, D. Smith and G. B. Hanna, Analyst, 2011, 136, 3233 DOI: 10.1039/C1AN15356K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements