Issue 11, 2012

The preparation and use of synthetic isotope mixtures for testing the accuracy of the PTIMS method for 10B/11B isotope ratio determination using boron mannitol complex and NaCl for the formation of Na2BO2+

Abstract

The development of a method for determination of isotopic composition requires calibration of the method over a wide range of isotopic ratios. Further, validation of data obtained by the method requires isotopic reference materials spanning a wide range of ratios. In the present studies, gravimetric synthetic mixtures of boron with 10% 10B to 95% 10B were prepared by mixing solutions of enriched boron isotopes. The solutions of 10B and 11B enriched isotopes were calibrated using isotopic reference material NIST SRM-951 as a spike for isotope dilution. 10B/11B atom ratios in all the blends were determined by Positive Thermal Ionization Mass Spectrometry (PTIMS) using NaCl with mannitol for the formation of Na2BO2+. A measurement precision of about 0.03% was obtained from repetitive P-TIMS analyses of the mixtures with 10B content ranging from 10 to 70%. An instrument isotope fractionation factor (K-factor) of 0.99935 ± 0.00030 (1 s) was obtained for 10B/11B atom ratios of the different blends and this agreed with the K-factor determined from P-TIMS analysis of NIST SRM-951. The different isotopic blends prepared were also used in Inductively Coupled Plasma Quadrupole Mass Spectrometry, (ICP-QMS) employing NIST SRM-951 (10B/11B ratio of 0.2473) as a bracketing standard. An accuracy and precision of about 0.5% was obtained during ICP-QMS analyses of these mixtures. A novel and simple method for validation of analysis methodology with synthetic mixtures prepared using enriched isotopes is described in the present work.

Graphical abstract: The preparation and use of synthetic isotope mixtures for testing the accuracy of the PTIMS method for 10B/11B isotope ratio determination using boron mannitol complex and NaCl for the formation of Na2BO2+

Article information

Article type
Paper
Submitted
29 Apr 2012
Accepted
25 Aug 2012
First published
29 Aug 2012

Anal. Methods, 2012,4, 3593-3599

The preparation and use of synthetic isotope mixtures for testing the accuracy of the PTIMS method for 10B/11B isotope ratio determination using boron mannitol complex and NaCl for the formation of Na2BO2+

R. M. Rao, A. R. Parab and S. K. Aggarwal, Anal. Methods, 2012, 4, 3593 DOI: 10.1039/C2AY25439E

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements