Issue 1, 2013

A compact comprehensive two-dimensional gas chromatography (GC×GC) approach for the analysis of biogenic VOCs

Abstract

We describe the development of a compact comprehensive two-dimensional gas chromatograph suitable for the measurement of biogenic VOCs in the atmosphere at part per billion mixing ratios. The design seeks to minimise instrument size and power consumption and maximise portability and autonomy. The instrument concept is to achieve high analyte selectivity for complex VOC mixture analysis using comprehensive two-dimensional GC (GC×GC), rather than hyphenation with larger more expensive detectors such as MS. Key features of the analytical approach are a custom-built miniature thermal desorption trap to collect and concentrate VOCs from the sample gas stream, a copper conducting direct column heating system and a valve-modulated interface to enable GC×GC. The high power and large form-factor turbulent GC oven is replaced by direct column heating (and cooling below ambient) by thermal transfer from copper bobbin holders with heating and cooling input from Peltier devices. The combination of two independent copper bobbins allows for independent control of the two columns needed for comprehensive GC. A heated two position 1/16′′ diaphragm valve is used to enable flow modulation between two columns, with analyte detection at the outlet of the second column using a miniaturised low cost photo-ionisation detector. The instrument sub-components are controlled by a Compact RIO computer (National Instruments) and purpose designed software written in LabVIEW allowing autonomous measurements. The complete system weighs 15 kg, is around the size of a desktop computer and has a mean power demand of 112 W when battery powered. Results on the sensitivity and linearity for isoprene collection and analysis of standard gas mixtures are presented along with a discussion of limiting factors that hinder field device performance.

Graphical abstract: A compact comprehensive two-dimensional gas chromatography (GC×GC) approach for the analysis of biogenic VOCs

Article information

Article type
Paper
Submitted
06 Jul 2012
Accepted
11 Oct 2012
First published
12 Oct 2012

Anal. Methods, 2013,5, 141-150

A compact comprehensive two-dimensional gas chromatography (GC×GC) approach for the analysis of biogenic VOCs

S. J. Edwards, A. C. Lewis, S. J. Andrews, R. T. Lidster, J. F. Hamilton and C. N. Rhodes, Anal. Methods, 2013, 5, 141 DOI: 10.1039/C2AY25710F

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements