Issue 9, 2012

Evaluation of colloidal silicagels for lead isotopic measurements using thermal ionisation mass spectrometry

Abstract

In this study we have investigated the suitability of silicagels from four companies (Merck, Sigma-Aldrich, Nissan Chemical and Alfa Aesar) as emission activators for ionisation of lead in thermal ionisation mass spectrometry (TIMS). We have tested U and Pb blank levels, ionisation efficiency, signal stability, degree of fractionation, and reproducibility and accuracy of the Pb isotopic ratios measured with these emitters. Further tests were undertaken to evaluate the dependency of ionisation efficiency on the particle size and concentration of silicagels and the mixing ratio of silicagel and phosphoric acid. Mass fractionation, reproducibility and stability of the ion beam were monitored using 300 pg of the lead isotopic standard SRM-981. The Merck and Sigma-Aldrich silicagels have the best performance as Pb ion emitters. They yielded accurate Pb isotopic ratios with precisions of ∼0.05% (2SD) for 207Pb/206Pb. We find that the ionisation efficiency does not depend on the particle size, but on silicagel concentration and proportion of silicagel to phosphoric acid. The highest ionisation efficiency (9.2 ± 2.2%, 2SE) was obtained using 0.004 ml of a silicagel from Sigma-Aldrich at a concentration of 0.4 wt% of SiO2 loaded with 0.05 ml of 0.02 N phosphoric acid. These results clearly indicate that the Sigma-Aldrich emitter is an excellent alternative for Pb isotopic measurements to the widely used, but no longer produced Merck silicagel. The silicagels from Alfa Aesar and Nissan Chemical have a high U background concentration compared to the Merck and Sigma-Aldrich gels, and produce less accurate Pb isotopic ratios.

Graphical abstract: Evaluation of colloidal silicagels for lead isotopic measurements using thermal ionisation mass spectrometry

Supplementary files

Article information

Article type
Paper
Submitted
07 Mar 2012
Accepted
30 May 2012
First published
30 May 2012

J. Anal. At. Spectrom., 2012,27, 1439-1446

Evaluation of colloidal silicagels for lead isotopic measurements using thermal ionisation mass spectrometry

M. H. Huyskens, T. Iizuka and Y. Amelin, J. Anal. At. Spectrom., 2012, 27, 1439 DOI: 10.1039/C2JA30083D

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements