Issue 12, 2014

Flow cytometric microsphere-based immunoassay as a novel non-radiometric method for the detection of glutamic acid decarboxylase autoantibodies in type 1 diabetes mellitus

Abstract

The first measurable sign of arising autoimmunity in type 1 diabetes mellitus is the detection of autoantibodies against beta-cell antigens, such as glutamic acid decarboxylase (GAD65). GAD65 autoantibodies (GADA) are usually measured by the Radioligand Binding Assay (RBA). The aim of this work was to develop protocols of flow cytometric microsphere-based immunoassays (FloCMIA) which involved glutamic acid decarboxylase fused to thioredoxin (TrxGAD65) adsorbed on polystyrene microspheres. Detection of bound GADA was accomplished by the use of anti-human IgG–Alexa Fluor 488 (protocol A), anti-human IgG–biotin and streptavidin–dichlorotriazinyl aminofluorescein (DTAF) (protocol B) or TrxGAD65–biotin and streptavidin–DTAF (protocol C). Serum samples obtained from 46 patients assayed for routine autoantibodies at Servicios Tecnológicos de Alto Nivel (STAN-CONICET) were analyzed by RBA, ELISA and three alternative FloCMIA designs. Protocol C exhibited the highest specificity (97.8%) and sensitivity (97.4%) and a wide dynamic range (1.00–134.40 SDs). Samples obtained from 40 new-onset diabetic patients were also analyzed to further evaluate the performance of protocol C. The latter protocol showed a sensitivity of 58.6% and a prevalence of 47.5%. Two patients resulted positive only by FloCMIA protocol C and its SDs were higher than those of RBA and ELISA, showing a significantly wide dynamic range. In conclusion, FloCMIA proved to be highly sensitive and specific, requiring a low sample volume; it is environmentally adequate, innovative and represents a cost-effective alternative to traditional GADA determination by RBA and/or ELISA, making it applicable to most medium-complexity laboratories.

Graphical abstract: Flow cytometric microsphere-based immunoassay as a novel non-radiometric method for the detection of glutamic acid decarboxylase autoantibodies in type 1 diabetes mellitus

Supplementary files

Article information

Article type
Paper
Submitted
04 Dec 2013
Accepted
11 Mar 2014
First published
12 Mar 2014

Analyst, 2014,139, 3017-3025

Flow cytometric microsphere-based immunoassay as a novel non-radiometric method for the detection of glutamic acid decarboxylase autoantibodies in type 1 diabetes mellitus

L. L. Guerra, A. Trabucchi, N. I. Faccinetti, R. F. Iacono, D. B. Ureta, E. Poskus and S. N. Valdez, Analyst, 2014, 139, 3017 DOI: 10.1039/C3AN02243A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements