Issue 17, 2013

A microbead-incorporated centrifugal sample pretreatment microdevice

Abstract

In this study, we present a novel bead-incorporated centrifugal sample pretreatment microdevice to purify influenza A H3N2 viral RNA. Simple revolution per minute (RPM) control can lead to RNA capture on a bead-bed, and the sequential loading of a washing solution and an elution solution. Tetraethoxy orthosilicate (TEOS)-treated glass microbeads were utilized as a capture matrix. The sample pretreatment microdevice consists of four reservoirs for storing an RNA sample, a washing solution, an elution solution, and a collected sample, and they were merged at the microbead-bed microchannel. The washing solution reservoir and the elution solution reservoir were connected to the bead-bed microchannel through a capillary valve and a siphon channel, respectively. An RNA sample (a lysed influenza A H3N2 virus), a washing solution (70% ethanol) and an elution solution (water or a reverse transcription-polymerase chain reaction (RT-PCR) cocktail) were loaded into the designated reservoirs, and they were successively transported to the bead-bed by RPM control owing to the optimized channel design. Purified RNAs could be obtained in 440 s. Then, a target H3 gene was amplified by an off-chip based real-time RT-PCR to evaluate the capture efficiency of RNA on our proposed microdevice. 81% of RNAs were successfully captured and purified. Interestingly, the use of the RT-PCR cocktail itself as an elution solution resulted in a 76% capture yield. Furthermore, we successfully performed RNA purification from the clinical nasopharyngeal swabs to identify the subtype of the influenza A virus. This platform provides high potential for the direct integration of the sample pretreatment microdevice into the downstream micro-PCR unit to create a total genetic analysis microsystem.

Graphical abstract: A microbead-incorporated centrifugal sample pretreatment microdevice

Supplementary files

Article information

Article type
Paper
Submitted
24 Feb 2013
Accepted
29 May 2013
First published
30 May 2013

Lab Chip, 2013,13, 3383-3388

A microbead-incorporated centrifugal sample pretreatment microdevice

J. H. Jung, B. H. Park, Y. K. Choi and T. S. Seo, Lab Chip, 2013, 13, 3383 DOI: 10.1039/C3LC50266J

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements