Sample pre-concentration with high enrichment factors at a fixed location in paper-based microfluidic devices

Abstract

The lack of sensitivity is a major problem among microfluidic paper-based analytical devices (μPADs) for early disease detection and diagnosis. Accordingly, the present study presents a method for improving the enrichment factor of low-concentration biomarkers by using shallow paper-based channels realized through a double-sided wax-printing process. In addition, the enrichment factor is further enhanced by exploiting the ion concentration polarization (ICP) effect on the cathodic side of the nanoporous membrane, in which a stationary sample plug is obtained. The occurrence of ICP on the shallow-channel μPAD is confirmed by measuring the current–voltage response as the external voltage is increased from 0 to 210 V (or the field strength from 0 to 1.05 × 104 V m−1) over 600 s. In addition, to the best of our knowledge, the electroosmotic flow (EOF) speed on the μPAD fabricated with a wax-channel is measured for the first time using a current monitoring method. The experimental results show that for a fluorescein sample, the concentration factor is increased from 130-fold in a conventional full-thickness paper channel to 944-fold in the proposed shallow channel. Furthermore, for a fluorescein isothiocyanate-labeled bovine serum albumin (FITC-BSA) sample, the proposed shallow-channel μPAD achieves an 835-fold improvement in the concentration factor. The concentration technique presented here provides a novel strategy for enhancing the detection sensitivity of μPAD applications.

Graphical abstract: Sample pre-concentration with high enrichment factors at a fixed location in paper-based microfluidic devices

Supplementary files

Article information

Article type
Paper
Submitted
06 Nov 2015
Accepted
29 Jan 2016
First published
29 Jan 2016

Lab Chip, 2016,16, 925-931

Author version available

Sample pre-concentration with high enrichment factors at a fixed location in paper-based microfluidic devices

S. Yeh, K. Chou and R. Yang, Lab Chip, 2016, 16, 925 DOI: 10.1039/C5LC01365H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements