Issue 8, 2011

A magnetic bead-based assay for the rapid detection ofmethicillin-resistant Staphylococcus aureus by using a microfluidic system with integrated loop-mediated isothermal amplification

Abstract

This study reports a new diagnostic assay for the rapid detection of methicillin-resistant Staphylococcus aureus (MRSA) by combing nucleic acid extraction and isothermal amplification of target nucleic acids in a magnetic bead-based microfluidic system. By using specific probe-conjugated magnetic beads, the target deoxyribonucleic acid (DNA) of the MRSA can be specifically recognized and hybridized onto the surface of the magnetic beads which are then mixed with clinical sample lysates. This is followed by purifying and concentrating the target DNA from the clinical sample lysates by applying a magnetic field. Nucleic acid amplification of the target genes can then be performed by the use of a loop-mediated isothermal amplification (LAMP) process via the incorporation of a built-in micro temperature control module, followed by analyzing the optical density (OD) of the LAMP amplicons using a spectrophotometer. Significantly, experimental results show that the limit of detection (LOD) for MRSA in the clinical samples is approximately 10 fg μL−1 by performing this diagnostic assay in the magnetic bead-based microfluidic system. In addition, the entire diagnostic protocol, from bio-sample pre-treatment to optical detection, can be automatically completed within 60 min. Consequently, this miniature diagnostic assay may become a powerful tool for the rapid purification and detection of MRSA and a potential point-of-care platform for detection of other types of infections.

Graphical abstract: A magnetic bead-based assay for the rapid detection of methicillin-resistant Staphylococcus aureus by using a microfluidic system with integrated loop-mediated isothermal amplification

Supplementary files

Article information

Article type
Paper
Submitted
21 Sep 2010
Accepted
10 Feb 2011
First published
11 Mar 2011

Lab Chip, 2011,11, 1521-1531

A magnetic bead-based assay for the rapid detection of methicillin-resistant Staphylococcus aureus by using a microfluidic system with integrated loop-mediated isothermal amplification

C. Wang, K. Lien, J. Wu and G. Lee, Lab Chip, 2011, 11, 1521 DOI: 10.1039/C0LC00430H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.