Previous studies have demonstrated the potential of multiple-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) for precise Pb isotopic measurements using admixed Tl for "external normalization" of instrumental mass discrimination. The Micromass IsoProbe is a new, single-focusing MC-ICP-MS instrument that does not employ an electrostatic sector for energy-focusing. Instead, a hexapole collision cell is used to thermalize the ion beam. This study presents the first in-depth investigation of the application of the IsoProbe to Pb isotope ratio measurements. With a Tl-based mass bias correction, multiple analyses of mixed Pb–Tl standard solutions typically display reproducibilities (±2σ) of about 50 ppm for 207Pb∶206Pb, 100 ppm for 208Pb∶206Pb and 206Pb∶204Pb, 150 ppm for 207Pb∶204Pb and 175 ppm for 208Pb∶204Pb. Using an empirically optimized exponential law normalization, the Pb isotope data show excellent agreement with reference values obtained by thermal ionization mass spectrometry. The cross-calibration between NIST SRM 981 and 982 demonstrates that accurate results can be obtained with this technique over a wide range of Pb isotopic compositions. The Tl-corrected Pb data obtained on the IsoProbe, however, display correlations with the Pb∶Tl ratio of the analyzed solutions. The addition of large amounts of Tl to the samples is unfavorable for the accurate measurement of the low-intensity 204Pb ion beam. Analytical artifacts may also be generated if high concentrations of concomitant elements are present in the sample solutions. Matrix effects and instrumental memory, however, can be readily overcome by the adoption of appropriate analytical protocols and it is demonstrated that sample measurements can achieve the same levels of precision and accuracy as are routinely obtained for analyses of pure standard solutions.

Article information

Article type
Paper
Submitted
30 Jun 2000
Accepted
07 Sep 2000
First published
25 Oct 2000

J. Anal. At. Spectrom., 2000,15, 1451-1460

Investigation of matrix effects for Pb isotope ratio measurements by multiple collector ICP-MS: verification and application of optimized analytical protocols

M. Rehkämper and K. Mezger, J. Anal. At. Spectrom., 2000, 15, 1451 DOI: 10.1039/B005262K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements