Issue 9, 2003

Investigation of non-spectroscopic interference and internal standardization method in axially and radially viewed inductively coupled plasma optical emission spectrometry using cross-flow and ultrasonic nebulization

Abstract

The matrix effects on radially and axially viewed inductively coupled plasma optical emission spectrometry (ICP-OES) equipped with cross-flow (CFN) and ultrasonic nebulizer (USN) were evaluated for the determination of multi-elements in various sample matrices. Na, Ca, Mg, Al, Mn, Cu, Si and Fe were used as matrix elements and the change in light intensities of selected analyte elements with a wide range of spectral lines differing in energy sum (summation of excitation energy and first ionization energy) were compared. From the correlation of the change in line intensity and energy sum of analyte elements and the second ionization energy of matrix elements, a novel observation on non-spectroscopic interference is described. Based on our experimental results, two types of non-spectroscopic interferences resulting from different matrix elements were observed, regardless of the sample introduction systems or observation modes. Moreover, besides the fact that the second ionization energy of matrix elements shows unique effect on the change in the analyte spectral lines, bigger matrix effect was found for analytical lines possessing energy sum larger than 14.03 eV in the presence of matrix elements with second ionization energy lower than 15.64 eV. The applicability of RF power adjustment and internal standardization were investigated for the compensation for matrix interferences. It was found that satisfactory corrected results can be achieved by the use of single internal standard as the second ionization energy of matrix element is higher than 15.75 eV. However, in view of the different depressive effect occurring in the analyte spectral lines, the the similarity in energy sum of analytical lines and internal standard has been confirmed by using two internal standards for compensating the matrix interferences caused by matrix elements with second ionization energy lower than 15.64 eV.

Article information

Article type
Paper
Submitted
20 Jan 2003
Accepted
18 Jul 2003
First published
01 Aug 2003

J. Anal. At. Spectrom., 2003,18, 1163-1170

Investigation of non-spectroscopic interference and internal standardization method in axially and radially viewed inductively coupled plasma optical emission spectrometry using cross-flow and ultrasonic nebulization

Y. Sun, S. Wu and C. Lee, J. Anal. At. Spectrom., 2003, 18, 1163 DOI: 10.1039/B300797A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.