Improved in situ measurements of lead isotopes in silicate glasses by LA-MC-ICPMS using multiple ion counters

Abstract

A new technique that improves the spatial resolution and quantification limits of the measurement of lead isotope ratios in silicate glasses with <15 μg g−1 total Pb by LA-MC-ICPMS is presented. The new method provides the capability of making quantitative, in situ lead isotope measurements on tiny objects of geologic interest such as mineral growth bands, melt inclusions, and accessory minerals, even where they are lead poor. The method allows for the concurrent, static measurement of 204Pb, 206Pb, 207Pb, 208Pb along with 202Hg in five Channeltron ion counters. Standard-sample-standard bracketing using USGS BCR2-G as the calibrant is used to correct for instrumental mass bias. Accuracy and precision of the method was evaluated by replicate analyses of various MPI-DING reference glasses with low lead concentrations (∼1–11 μg g−1) and well-determined isotopic ratios. Spot sizes for in situ analyses were as small as 40–69 μm, providing better spatial resolution than previous LA-MC-ICPMS results reporting 204Pb. Measured lead isotope ratios for the MPI-DING reference glasses T1-G (11.6 μg g−1 total Pb) and ATHO-G (5.67 μg g−1 total Pb) agree within 0.10% and 0.15% respectively of the preferred values using 40 μm spots. For MPI-DING KL2-G (2.07 μg g−1 total Pb) and ML3B-G (1.38 μg g−1 total Pb) measured lead ratios agree within 0.75% of the accepted values with typical precisions of <1.9% (2RSD) using 69 μm spots; measured 207Pb/206Pb and 208Pb/206Pb are within 0.45% of preferred values with precisions of <0.50% (2RSD). These results demonstrate improvement over previous LA-MC-ICPMS data in terms of both quantification limits and spatial resolution, while retaining similar levels of accuracy and precision.

Graphical abstract: Improved in situ measurements of lead isotopes in silicate glasses by LA-MC-ICPMS using multiple ion counters

Article information

Article type
Paper
Submitted
11 Sep 2007
Accepted
10 Dec 2007
First published
08 Jan 2008

J. Anal. At. Spectrom., 2008,23, 535-543

Improved in situ measurements of lead isotopes in silicate glasses by LA-MC-ICPMS using multiple ion counters

A. Kate Souders and P. J. Sylvester, J. Anal. At. Spectrom., 2008, 23, 535 DOI: 10.1039/B713934A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements