Issue 10, 2009

JEM Spotlight: Monitoring the treatment efficiency of a full scale ozonation on a sewage treatment plant with a mode-of-action based test battery

Abstract

Tertiary treatment of wastewater with ozone is a promising technique for removing residual micropollutants that remain after secondary biological treatment. We monitored the performance of a full-scale ozonation reactor on a sewage treatment plant in Switzerland with a screening battery of bioassays. Six toxicity endpoints were selected that covered non-specific toxicity, as well as selected receptor-mediated modes of action and reactive toxicity. Non-specific toxicity was assessed with two bioassays, the bioluminescence inhibition of the marine luminescent bacterium Vibrio Fischeri and the growth inhibition of the green algae Pseudokirchneriella subcapitata. Treatment efficiency was around 90% for the secondary treatment, but only 65% and 76% for the ozonation step in the two non-specific endpoints, respectively. This finding is consistent with this type of oxidation reaction because ozone only modifies the organic molecules but does not mineralize them fully leaving residual toxicity of the transformation products. In contrast, the specific receptor-mediated endpoints of inhibition of photosystem II in algae and estrogenicity were largely reduced by ozonation. While compounds inhibiting photosynthesis proved to be rather recalcitrant toward biological treatment with only 47% removal, an additional 86% removal by ozonation yielded an overall treatment efficiency in the entire treatment chain of 89%. The effect on estrogenicity, quantified with the yeast estrogen screen, was even more significant: A treatment efficiency of 95% in the secondary treatment, 86% during ozonation plus a small effect by biological sand filtration yielded an overall treatment efficiency of 99.5%. Insecticides that inhibit acetylcholinesterase were fairly resistant to degradation, but an overall treatment efficiency of 91% was achieved in two steps: 72% in biological treatment and 60% during ozonation. Finally, no significant genotoxicity was observed with the umuC test after ozonation, while the influent showed a genotoxic response when it was enriched by a factor of 15 to 60. Treatment efficiency increased with the ozone dose and remained virtually unchanged over ozone doses above 500 g ozone per kg dissolved organic carbon. The reduction of toxicity can be rationalized by the chemical oxidation processes likely to occur for each group of chemicals that are typical for a given mode of toxic action. For comparison, tertiary treatment with powdered activated carbon was also evaluated, which poses a viable alternative to ozonation with respect to removal of micropollutants.

Graphical abstract: JEM Spotlight: Monitoring the treatment efficiency of a full scale ozonation on a sewage treatment plant with a mode-of-action based test battery

Supplementary files

Article information

Article type
Paper
Submitted
07 Apr 2009
Accepted
02 Jul 2009
First published
15 Jul 2009

J. Environ. Monit., 2009,11, 1836-1846

JEM Spotlight: Monitoring the treatment efficiency of a full scale ozonation on a sewage treatment plant with a mode-of-action based test battery

B. I. Escher, N. Bramaz and C. Ort, J. Environ. Monit., 2009, 11, 1836 DOI: 10.1039/B907093A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Spotlight

Advertisements