Validation of a centrifugal microfluidic sample lysis and homogenization platform for nucleic acidextraction with clinical samples

Abstract

The applications of microfluidic technologies in medical diagnostics continue to increase, particularly in the field of nucleic acid diagnostics. While much attention has been focused on the development of nucleic acid amplification and detection platforms, sample preparation is often taken for granted or ignored all together. Specifically, little or no consideration is paid to the development of microfluidic systems that efficiently extract nucleic acids from biological samples. Here, a centrifugal microfluidic platform for mechanical sample lysis and homogenization is presented. The system performs sample lysis through a magnetically actuated bead-beating system followed by a centrifugal clarification step. The supernatant is then transferred for extraction using a unique siphon. Several other new microfluidic functions are implemented on this centrifugal platform as well, including sample distribution, a unique hydraulic capillary valve, and self-venting. Additionally, the improved system has features with a small footprint designed specifically for integration with further downstream processing steps. Biological validation of the platform is performed using Bacillus subtilis spores and clinical samples (nasopharyngeal aspirates) for respiratory virus detection. The platform was found to be as efficient as in-tube bead-beating lysis and homogenization for nucleic acid extraction, and capable of processing 4 samples in batch to near PCR-ready products in under 6 min.

Graphical abstract: Validation of a centrifugal microfluidic sample lysis and homogenization platform for nucleic acid extraction with clinical samples

Supplementary files

Article information

Article type
Paper
Submitted
03 Jul 2009
Accepted
20 Oct 2009
First published
23 Nov 2009

Lab Chip, 2010,10, 363-371

Validation of a centrifugal microfluidic sample lysis and homogenization platform for nucleic acid extraction with clinical samples

J. Siegrist, R. Gorkin, M. Bastien, G. Stewart, R. Peytavi, H. Kido, M. Bergeron and M. Madou, Lab Chip, 2010, 10, 363 DOI: 10.1039/B913219H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements