Issue 11, 2011

Passive ammonia monitoring in the United States: Comparing three different sampling devices

Abstract

The need for ambient gaseous ammonia (NH3) measurements has increased in the last decade as reactive NH3 concentrations and deposition fluxes show little change even with tightening standards on nitrogen oxides (NOx) emissions. Currently, there are several networks developing methods for adding NH3 measurements in the U.S. Gaseous NH3 measurements will provide scientists and policymakers data which can be used to estimate ecosystem inputs, validate air quality models including trends and regional variability, and evaluate changes to the environment based on additional emission reduction requirements and estimates of critical nitrogen load exceedances. The passive samplers described in this paper were deployed in duplicate or triplicate and collocated with annular denuders or continuous instruments to determine their accuracy. The samplers assessed included the Adapted Low-Cost Passive High Absorption (ALPHA), Radiello®, and Ogawa passive samplers. The median relative percent differences (MRPD) between the reference method and passive samplers for the ALPHA, Radiello® and Ogawa were −2.4%, −37% and −44%, respectively. The precision between duplicate samplers for the ALPHA and Ogawa samplers, was 7% and 6%, respectively. Triplicate Radiello® precision was assessed using the coefficient of variation (CV). The CV for the Radiello® samplers was 10%. This article discusses the statistical results from these studies.

Graphical abstract: Passive ammonia monitoring in the United States: Comparing three different sampling devices

Supplementary files

Article information

Article type
Paper
Submitted
08 Jul 2011
Accepted
21 Sep 2011
First published
19 Oct 2011

J. Environ. Monit., 2011,13, 3156-3167

Passive ammonia monitoring in the United States: Comparing three different sampling devices

M. A. Puchalski, M. E. Sather, J. T. Walker, C. M. B. Lehmann, D. A. Gay, J. Mathew and W. P. Robarge, J. Environ. Monit., 2011, 13, 3156 DOI: 10.1039/C1EM10553A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Spotlight

Advertisements