Issue 1, 2013

Dispersive liquid–liquid micro extraction of boron as tetrafluoroborate ion (BF4) from natural waters, wastewater and seawater samples and determination using a micro-flow nebulizer in inductively coupled plasma-quadrupole mass spectrometry

Abstract

Boron, present in groundwater and seawater, is extracted as tetrafluoroborate anion by dispersive liquid–liquid microextraction (DLLME) and determined by inductively coupled plasma quadrupole mass spectrometry (ICP-QMS). A low flow rate (200 μL min−1) SeaSpray™ micro-flow nebulizer was used for the sample introduction. In this method, the tetrafluoroborate anion formed in the presence of 0.9 mol L−1 H2SO4 and 0.1 mol L−1 F was extracted into chloroform in the presence of Aliquat® 336 (tricaprylmethylammonium chloride) at room temperature. The bulky cationic surfactant, Aliquat® 336, acts as a phase transfer agent, which not only forms an ion-pair complex with tetrafluoroborate anion but also helps in the rapid conversion of boric acid to BF4 ion. The tetrafluoroborate anion was back-extracted from the chloroform layer with nitric acid for determination by ICP-QMS. Effective parameters for the complex formation and its extraction, such as volume of extractant/disperser solvent, extraction time and concentration of the surfactant have been optimized. Under optimum conditions, an average preconcentration factor of 18 was obtained for 8 mL of water sample for determination by ICP-QMS. The calibration graph was linear in the range of 1–50 μg L−1 for boron, with a limit of detection of 0.3 μg L−1, calculated based on 3 s of blank (n = 6). The precision was close to 3% R.S.D. (n = 3), when processing 8 mL aliquots of sample. The method has been applied to determine boron in bottled mineral water, groundwater, wastewater and seawater samples. The recoveries obtained for the boron spiked to 30 μg L−1 levels in these water samples were 97–102%.

Graphical abstract: Dispersive liquid–liquid micro extraction of boron as tetrafluoroborate ion (BF4−) from natural waters, wastewater and seawater samples and determination using a micro-flow nebulizer in inductively coupled plasma-quadrupole mass spectrometry

Article information

Article type
Paper
Submitted
28 Sep 2012
Accepted
01 Nov 2012
First published
02 Nov 2012

J. Anal. At. Spectrom., 2013,28, 142-149

Dispersive liquid–liquid micro extraction of boron as tetrafluoroborate ion (BF4) from natural waters, wastewater and seawater samples and determination using a micro-flow nebulizer in inductively coupled plasma-quadrupole mass spectrometry

K. Chandrasekaran, D. Karunasagar and J. Arunachalam, J. Anal. At. Spectrom., 2013, 28, 142 DOI: 10.1039/C2JA30272A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements