Issue 5, 2014

Reduction of nonspecific protein adsorption on cantilever biosensors caused by transverse resonant mode vibration

Abstract

We examine if vibration of millimeter-sized cantilever sensors can release nonspecifically adsorbed proteins. Integrated electrochemical and mass-change measurement as well as fluorescence assays showed transverse surface vibration released nonspecifically bound proteins in samples prepared at 0.2–3.6 mg bovine serum albumin (BSA) per mL. Extent of release was directly related to magnitude of excitation voltage (Vex) applied to the self-actuating lead zirconate titanate (PZT) cantilever over three log units (0, 10 mV, 100 mV, and 1 V). Vibration-induced release was not instantaneous, but had an apparent first-order rate constant (kapp) which ranged from 0.02–0.1 min−1. Results suggest significant serum albumin protein release could be achieved using excitation voltages of 1 V in millimeter-sized cantilever sensors. Complementary experiments with thiolated DNA, which binds to surface gold 〈111〉 sites with ∼ four times higher binding energy than BSA, showed negligible release under the same vibration magnitude. The results of the study suggest a direct correlation between surface-adsorbate binding energy and the effectiveness of vibration-induced release. We suggest that the release mechanism includes contributions from surface strain energy, body force, and acoustic streaming-associated hydrodynamic effects. The primary contribution of this study suggests that surface vibration of cantilever sensors may be useful in reducing nonspecific adsorption, especially for biosensing of analytes present in a complex background.

Graphical abstract: Reduction of nonspecific protein adsorption on cantilever biosensors caused by transverse resonant mode vibration

Supplementary files

Article information

Article type
Paper
Submitted
04 Sep 2013
Accepted
02 Jan 2014
First published
06 Jan 2014

Analyst, 2014,139, 1112-1120

Reduction of nonspecific protein adsorption on cantilever biosensors caused by transverse resonant mode vibration

B. N. Johnson and R. Mutharasan, Analyst, 2014, 139, 1112 DOI: 10.1039/C3AN01675G

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements