Issue 4, 2014

Multiplex chemiluminescent immunoassay for screening of mycotoxins using photonic crystal microsphere suspension array

Abstract

A novel multiplex chemiluminescent mycotoxin immunoassay suspension array system was developed by combining the silica photonic crystal microspheres (SPCMs) encoding technique and a chemiluminescent immunoassay (CLIA) method. The SPCMs were used as a carrier of the suspension array and encoded by their reflectance peak positions, which overcome fluorescence photobleaching, and the potential interference between the encoding fluorescence and detection fluorescence. Aflatoxin B1 (AFB1), fumonisin B1 (FB1) and ochratoxin A (OTA) artificial antigens were immobilized on the surfaces of SPCMs by using 3-glycidoxypropyltrimethoxysilane as a linker. Horseradish peroxidase (HRP) was used as a labeling enzyme for the secondary antibody in the enzyme-catalyze H2O2–luminol chemiluminescence system. The CLIA detection system was easily integrated with a multifunctional microplate reader and displayed a two to three orders of magnitude dynamic linear detection range from 0.001 to 1, 0.001 to 1, and 0.01 to 1 ng mL−1 for AFB1, FB1 and OTA with 50% inhibitory concentrations (IC50) of 0.01, 0.036, and 0.04 ng mL−1, respectively. The recovery rates are in the range of 63.5 to 121.6% for the three mycotoxins in three kinds of spiked cereal samples. The results of detection in 12 naturally contaminated cereal samples were consistent with that of the classic enzyme-linked immunosorbent assay (ELISA) method. This proposed system is simple, rapid, low cost and high throughput for multiplex mycotoxin assay.

Graphical abstract: Multiplex chemiluminescent immunoassay for screening of mycotoxins using photonic crystal microsphere suspension array

Supplementary files

Article information

Article type
Paper
Submitted
29 Oct 2013
Accepted
29 Nov 2013
First published
29 Nov 2013

Analyst, 2014,139, 771-777

Multiplex chemiluminescent immunoassay for screening of mycotoxins using photonic crystal microsphere suspension array

K. Xu, Y. Sun, W. Li, J. Xu, B. Cao, Y. Jiang, T. Zheng, J. Li and D. Pan, Analyst, 2014, 139, 771 DOI: 10.1039/C3AN02032K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements