Issue 9, 2013

Ion pairing and ion exchange chromatography coupled to ICP-MS to determine selenium species in human urine

Abstract

In this work three analytical methods were developed and applied to determine a broad spectrum of selenium species in human urine. The methods are based on different liquid chromatographic separation techniques (ion pairing, anion exchange and cation exchange chromatography) coupled to an inductively coupled plasma-mass spectrometer (ICP-MS) for selenium specific detection. They were adjusted for the determination of nine species named selenate (Se(VI)), selenite (Se(IV)), trimethylselenium ion (TMSe), methylselenoglutathione (SeMeG), methyl-2-acetamido-2-deoxy-1-seleno-β-D-galactopyranoside (SeSug1), methyl-2-amino-2-deoxy-1-seleno-β-D-galactopyranoside (SeSug3), selenomethionine (SeMet), selenoethionine (SeEt), methylselenocysteine (SeMCys) and provide detection limits between 0.10 and 0.19 μg Se per L. The procedures were applied to 45 urine samples of individuals of the general population. SeSug1 was detected in 100% (median: 1.79 μg g−1 creatinine; range: 0.47–8.97 μg g−1 creatinine) and SeSug3 (0.80; 0.07–3.53 μg Se per g creatinine) in 80% of the study population. SeSug1 and SeSug3 were strongly correlated; however a shift of their relation was observed in dependence of the exposure level. In 20% of the samples compounds were detected, which could be related to Se(VI) (0.12; 0.03–1.12 μg Se per g creatinine) and SeMCys (0.13; 0.03–0.41 μg Se per g creatinine). TMSe was detected in 18% of the samples. But whenever TMSe was detected, it was found in considerable concentrations (2.91; 2.72–4.42 μg Se per g creatinine). The species SeMet, SeEt, SeMeG and Se(IV) were not detected in any of the samples. The results of the study are consistent with the literature in which SeSug1 is well-established as major selenium species in human urine since years. Moreover, the results show that the composition of urinary eliminated Se-species might change depending on the Se exposure level. Finally, the results indicate a polymorphic selenium metabolism related to the formation of TMSe.

Graphical abstract: Ion pairing and ion exchange chromatography coupled to ICP-MS to determine selenium species in human urine

Article information

Article type
Paper
Submitted
12 Mar 2013
Accepted
30 May 2013
First published
30 May 2013

J. Anal. At. Spectrom., 2013,28, 1402-1409

Ion pairing and ion exchange chromatography coupled to ICP-MS to determine selenium species in human urine

T. Jäger, H. Drexler and T. Göen, J. Anal. At. Spectrom., 2013, 28, 1402 DOI: 10.1039/C3JA50083G

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements