Issue 10, 2013

Ionic liquid based carrier mediated hollow fiber liquid liquid liquid microextraction combined with HPLC-ICP-MS for the speciation of phenylarsenic compounds in chicken and feed samples

Abstract

A novel method of ionic liquid based carrier mediated hollow fiber liquid liquid liquid microextraction (IL-carrier mediated HF-LLLME) combined with high performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICP-MS) has been developed for the speciation of five phenylarsenic compounds and arsenate in chicken and feed samples. The target arsenic species were extracted from 6 mL aqueous samples (pH = 10.2) into an organic phase (20% (v/v) [MTOA]+[Cl] in toluene) impregnated in the pores of a hollow fiber, then back extracted into a 10 μL acceptor phase of 0.3 mol L−1 NaBr in the lumen of the hollow fiber. The main driving force for the extraction was the gradient concentration of the counter ion from the donor phase to the acceptor phase. Factors affecting the extraction of the target arsenic species were investigated in detail. Under the optimal conditions, the limits of detection (LODs, 3σ) for five target phenylarsenic compounds and arsenate were in the range of 1.4–16.0 ng L−1 with the relative standard deviations (CAs(V),4-OH,3-NHPAA,PA,4-NPAA = 0.05 μg L−1, Cp-ASA = 0.10 μg L−1, n = 7) ranging from 3.6 to 10.0%, and the enrichment factors were varied from 86 to 372-fold. The proposed method of IL-carrier mediated HF-LLLME-HPLC-ICP-MS was successfully applied to the determination of five phenylarsenic compounds and arsenate in chicken and feed samples with the recoveries of 79.2–105.4% and 81.1–117.8% for the spiked chicken and spiked feed samples, respectively.

Graphical abstract: Ionic liquid based carrier mediated hollow fiber liquid liquid liquid microextraction combined with HPLC-ICP-MS for the speciation of phenylarsenic compounds in chicken and feed samples

Article information

Article type
Paper
Submitted
28 Jul 2013
Accepted
14 Aug 2013
First published
14 Aug 2013

J. Anal. At. Spectrom., 2013,28, 1638-1647

Ionic liquid based carrier mediated hollow fiber liquid liquid liquid microextraction combined with HPLC-ICP-MS for the speciation of phenylarsenic compounds in chicken and feed samples

X. Guo, B. Chen, M. He, B. Hu and X. Zhou, J. Anal. At. Spectrom., 2013, 28, 1638 DOI: 10.1039/C3JA50243K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements