Comparison of microsublimation and ion exchange chromatography for boron isolation preceding its isotopic analysis via multi-collector ICP-MS

Abstract

Boron isotopic analysis is of interest in many research fields and for a large variety of sample types. Accurate and precise determination of boron isotope ratios using multi-collector ICP-mass spectrometry or thermal ionization mass spectrometry requires isolation of the target element prior to isotopic analysis, which is accomplished using either ion exchange chromatography or microsublimation. This study systematically compares the two methods in terms of B recovery, procedural blank, matrix removal efficiency, accuracy and precision of the resulting δ11B values as measured using multi-collector ICP-mass spectrometry, as well as labor intensiveness and costs. For this purpose, four types of sample matrices, i.e. 20 g L−1 Ca aqueous solution, seawater, digests of spinach (100 g L−1) and silicate glass (10 g L−1), were stripped from their original B content and spiked with B of known isotopic composition and were then subjected to both sample preparation methods and subsequent isotopic analysis of the purified B fraction via multi-collector ICP-mass spectrometry. For both methods, the highest (quantitative) B recoveries were obtained for Ca-rich aqueous solution and seawater. For spinach, accurate δ11B values were obtained after ion exchange chromatography. However, microsublimation was plagued by isotope fractionation, resulting in large offsets (∼8‰) between the experimental results and the corresponding reference values. For glass, B recovery was incomplete, nevertheless the absence of fractionation rendered both sample preparation methods suitable. Overall, in the absence of isotope fractionation, microsublimation appears advantageous in terms of procedural blanks, matrix removal efficiency, precision (2 s) on δ11B values, labor intensiveness and costs.

Graphical abstract: Comparison of microsublimation and ion exchange chromatography for boron isolation preceding its isotopic analysis via multi-collector ICP-MS

Supplementary files

Article information

Article type
Paper
Submitted
31 Mar 2014
Accepted
09 Jul 2014
First published
09 Jul 2014

J. Anal. At. Spectrom., 2014,29, 1819-1826

Author version available

Comparison of microsublimation and ion exchange chromatography for boron isolation preceding its isotopic analysis via multi-collector ICP-MS

K. Van Hoecke, V. Devulder, P. Claeys, P. Degryse and F. Vanhaecke, J. Anal. At. Spectrom., 2014, 29, 1819 DOI: 10.1039/C4JA00111G

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements