Evaluation of mixing devices and connection mode in the determination of Pb in glass using online isotope dilution laser ablation-ICP-MS

Abstract

Online isotope dilution laser ablation ICP-MS (ID-LA-ICP-MS) is considered a labor-saving, easy and accurate quantification technique when dealing with solid samples. However, in the mixing process of spike-sample aerosols, it is difficult for the aerosols to reach full isotopic equilibrium before being introduced to ICP-MS. Therefore, the poor and unstable mixing efficiency may result in an unstable isotope ratio, which cannot be accurately determined when using online ID-LA-ICP-MS. In this work, to improve the mixing efficiency and achieve a good isotopic equilibrium, four different mixing devices (devices A–D) were designed. Further, to comprehensively evaluate the mixing efficiency of the different devices, the signal sensitivity, trueness and precision of the blended 208Pb/207Pb ratio of each device in different connection modes (pre- or post-cell introduction of a 207Pb spike) were investigated. Of all the four devices, the assembly of device B in a pre-cell connection mode showed optimal performance in three aspects: (1) good trueness and consistency of the blended 208Pb/207Pb ratio; (2) good precision of the measured 208Pb/207Pb ratio (1.5–2.5%); (3) less signal sensitivity loss (0.6–0.7-fold less than in the post-cell mode). Using device B and a pre-cell connection approach, Pb in glass (NIST SRM610) was determined and a good agreement with the certified value was achieved. This work will help make the online ID-LA-ICP-MS method more accurate and precise.

Graphical abstract: Evaluation of mixing devices and connection mode in the determination of Pb in glass using online isotope dilution laser ablation-ICP-MS

Article information

Article type
Technical Note
Submitted
16 Jun 2014
Accepted
14 Aug 2014
First published
14 Aug 2014

J. Anal. At. Spectrom., 2014,29, 2183-2189

Evaluation of mixing devices and connection mode in the determination of Pb in glass using online isotope dilution laser ablation-ICP-MS

L. Feng and J. Wang, J. Anal. At. Spectrom., 2014, 29, 2183 DOI: 10.1039/C4JA00195H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements