Issue 2, 2015

Isotopic composition analysis of dissolved mercury in seawater with purge and trap preconcentration and a modified Hg introduction device for MC-ICP-MS

Abstract

This study aimed to solve the common problems in Hg isotope analysis of water samples at low concentration. The isotope composition of dissolved Hg in seawater is reported for the first time. A modified device for introducing Hg into a multi-collector inductively coupled plasma mass spectrometer and a preconcentration method for the preconcentration of dissolved Hg were developed to enhance the sensitivity of the isotopic composition analysis method. The modified cold-vapor generator was used to transfer dissolved Hg2+ from the matrix into gaseous Hg0. The purge and trap method was developed and employed to preconcentrate dissolved Hg in water samples. Keeping other parameters the same, the Hg signal generated with the modified Hg introduction device was twice as much as the commercial one (HGX 200). In the measurement of NIST SRM 3133, the external precision for δ202Hg was 0.06‰ (2SD, n = 310), and the δ202Hg value of the UM-Almadén in-house secondary standard was −0.57 ± 0.10‰ (2SD, n = 49), indicating that the modified device was stable and reliable. Factors influencing the efficiency of the purge and trap method, e.g., concentration of KMnO4 in the trapping solution, flow rate of the purge gas and purge time, were optimized. With ultrapure water (blank) and seawater (matrix) spiked with NIST SRM 3133 at Hg concentrations of 5.00–35.50 ng L−1 and 10.00–35.50 ng L−1, the δ202Hg values of the blank spike and matrix spike were 0.00 ± 0.04‰ (2SD, n = 19) and −0.02 ± 0.04‰ (2SD, n = 12), respectively. The results indicated that the purge and trap method was free from matrix interference. The results of this practical application showed good stability and reproducibility of the proposed methods.

Graphical abstract: Isotopic composition analysis of dissolved mercury in seawater with purge and trap preconcentration and a modified Hg introduction device for MC-ICP-MS

Article information

Article type
Paper
Submitted
22 Jul 2014
Accepted
20 Oct 2014
First published
20 Oct 2014

J. Anal. At. Spectrom., 2015,30, 353-359

Author version available

Isotopic composition analysis of dissolved mercury in seawater with purge and trap preconcentration and a modified Hg introduction device for MC-ICP-MS

H. Lin, D. Yuan, B. Lu, S. Huang, L. Sun, F. Zhang and Y. Gao, J. Anal. At. Spectrom., 2015, 30, 353 DOI: 10.1039/C4JA00242C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements