Issue 6, 2015

A sensitive impedimetric DNA biosensor for the determination of the HIV gene based on electrochemically reduced graphene oxide

Abstract

A sensitive impedimetric DNA biosensor for the determination of the HIV-1 gene was developed by employing electrochemically reduced graphene oxide (ERGO) as a sensing platform. The DNA biosensor was fabricated by drop-coating graphene oxide (GO) on a glassy carbon (GC) electrode and covalently immobilizing the designed single-stranded DNA (ssDNA) probe onto the GO using carbodiimide chemistry. The GO was later electrochemically reduced to obtain ERGO and applied to genosensing. Upon the occurrence of hybridisation events between the surface-confined ssDNA probe with the target DNA in solution to form double-stranded DNA (dsDNA) at the electrode surface, the negative charge in the electrode/electrolyte interface, and as such, the electron transfer resistance of the electrodes toward the [Fe(CN)6]3−/4− redox couple were changed. This change was used for impedimetric DNA biosensing. It was found that the employment of ERGO as an immobilization platform efficiently accelerated the electron transfer and enhanced the EIS response of the DNA biosensor. Under the conditions employed in this study, the change in the electron transfer resistance was linear with the logarithm of the concentration of target DNA within a concentration range of 1.0 × 10−12 to 1.0 × 10−9 M, with a detection limit of 3.0 × 10−13 M (S/N = 3). This strategy eliminated the requirement for DNA labelling, greatly simplifying the procedure. This work demonstrates that the employment of GO as an immobilization platform and ERGO as a biosensing platform is a promising approach to designing impedimetric aptasensors with high sensitivity and selectivity.

Graphical abstract: A sensitive impedimetric DNA biosensor for the determination of the HIV gene based on electrochemically reduced graphene oxide

Article information

Article type
Paper
Submitted
14 Jan 2015
Accepted
20 Jan 2015
First published
20 Jan 2015

Anal. Methods, 2015,7, 2554-2562

Author version available

A sensitive impedimetric DNA biosensor for the determination of the HIV gene based on electrochemically reduced graphene oxide

Q. Gong, H. Yang, Y. Dong and W. Zhang, Anal. Methods, 2015, 7, 2554 DOI: 10.1039/C5AY00111K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements