Issue 4, 2016

Molybdenum isotopic analysis by negative thermal ionization mass spectrometry (N-TIMS): effects on oxygen isotopic composition

Abstract

We developed a new, highly precise, and accurate Mo isotope analysis by thermal ionization mass spectrometry in negative ionization mode (N-TIMS). We discovered that the optimal condition to ionize Mo most efficiently into MoO3 was to load the Mo sample on a Re filament and cover the sample with La(NO3)3, thus yielding La/Mo = 5. To achieve highly precise Mo isotope analysis, determining the oxygen isotopic composition of MoO3 ions in each measurement by monitoring masses 149 (100Mo16O217O) and 150 (100Mo16O218O) ions and using the data for correcting for the O isotope interferences is important. After correcting the O isotopic interference and performing mass-dependent fractionation during the TIMS measurement, the acquired Mo isotopic ratios yielded the following reproducibilities (2SD): 47, 16, 10, 13, and 33 ppm for 92Mo/96Mo, 94Mo/96Mo, 95Mo/96Mo, 97Mo/96Mo, and 100Mo/96Mo, respectively. The reproducibilities have been improved by 1.3–2.7 times compared to those obtained in previous studies using multi-collector inductively coupled plasma mass spectrometry. The accuracy of our technique was confirmed by measuring two synthesized solutions with enriched 92Mo, 97Mo, and 100Mo abundances and two iron meteorites, i.e., Henbury (IIIAB) and Albion (IVA). Moreover, we determined positive Mo isotope anomalies for a new iron meteorite, Tambo Quemado (IIIAB). Our N-TIMS technique can be applied to the studies of nucleosynthetic isotope anomalies in extraterrestrial materials as well as mass-dependent Mo isotopic shift in environmental samples.

Graphical abstract: Molybdenum isotopic analysis by negative thermal ionization mass spectrometry (N-TIMS): effects on oxygen isotopic composition

Article information

Article type
Paper
Submitted
08 Sep 2015
Accepted
03 Feb 2016
First published
05 Feb 2016

J. Anal. At. Spectrom., 2016,31, 948-960

Author version available

Molybdenum isotopic analysis by negative thermal ionization mass spectrometry (N-TIMS): effects on oxygen isotopic composition

Y. Nagai and T. Yokoyama, J. Anal. At. Spectrom., 2016, 31, 948 DOI: 10.1039/C5JA00381D

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements