Issue 7, 2015

Circulating tumor cell detection using a parallel flow micro-aperture chip system

Abstract

We report on-chip isolation and detection of circulating tumor cells (CTCs) from blood samples using a system that integrates a microchip with immunomagnetics, high-throughput fluidics and size-based filtration. CTCs in a sample are targeted via their surface antigens using magnetic beads functionalized with antibodies. The mixture is then run through a fluidic chamber that contains a micro-fabricated chip with arrays of 8 μm diameter apertures. The fluid runs parallel to the microchip while a magnetic field is generated underneath to draw the beads and cells bound to them toward the chip surface for detection of CTCs that are larger than the apertures and clear out free beads and other smaller particles bound to them. The parallel flow configuration allows high volumetric flow rates, which reduces nonspecific binding to the chip surface and enables multiple circulations of the sample fluid through the system in a short period of time. In this study we first present models of the magnetic and fluidic forces in the system using a finite element method. We then verify the simulation results experimentally to determine an optimal flow rate. Next, we characterize the system by detecting cancer cell lines spiked into healthy human blood and show that on average 89% of the spiked MCF-7 breast cancer cells were detected. We finally demonstrate detection of CTCs in 49 out of 50 blood samples obtained from non-small cell lung cancer (NSCLC) patients and pancreatic cancer (PANC) patients. The number of CTCs detected ranges from 2 to 122 per 8 mL s of blood. We also demonstrate a statistically significant difference between the CTC counts of NSCLC patients who have received therapy and those who have not.

Graphical abstract: Circulating tumor cell detection using a parallel flow micro-aperture chip system

Supplementary files

Article information

Article type
Paper
Submitted
27 Jan 2015
Accepted
09 Feb 2015
First published
09 Feb 2015

Lab Chip, 2015,15, 1677-1688

Author version available

Circulating tumor cell detection using a parallel flow micro-aperture chip system

C. Chang, W. Huang, S. I. Jalal, B. Chan, A. Mahmood, S. Shahda, B. H. O'Neil, D. E. Matei and C. A. Savran, Lab Chip, 2015, 15, 1677 DOI: 10.1039/C5LC00100E

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements