Issue 21, 2015

Aggregation induced emission based fluorescence pH and temperature sensors: probing polymer interactions in poly(N-isopropyl acrylamide-co-tetra(phenyl)ethene acrylate)/poly(methacrylic acid) interpenetrating polymer networks

Abstract

Aggregation induced emission (AIE) active copolymers P1–P6 with high molecular weights (14 000–17 000) and low polydispersity indices (1.3–1.4) were prepared through copolymerization of N-isopropyl acrylamide (NIPAM) and tetra(phenyl)ethene (TPE)-based acrylate monomers. Copolymers P1–P6 show comparable thermal stability to poly(N-isopropylacrylamide) (PNIPAM), while their glass transition temperatures are higher by 7–9 °C than those of pristine PNIPAM. Copolymers P1–P6 are soluble in common organic solvents as well as in water. They retain a similar thermal sensitivity to PNIPAM, but their lower critical solution temperatures (LCST) are reduced with increase of TPE content. By changing the molar ratio of P1–P6/poly(methacrylic acid) (PMAA) and pH, complexes P1–P6–PMMA were studied by fluorescence spectroscopy and dynamic light scattering (DLS). The complexes are non-emissive in THF, and their fluorescence can be turned on upon addition of water. Moreover, their fluorescence is enhanced with the decrease in pH values due to the formation of interpenetrating polymer networks (IPNs) through inter-polymer hydrogen bonding. Fluorescence spectroscopy and DLS results also reveal that the phase transition behaviour of IPNs upon heating could be significantly modified by pH change. Reduction in the pH value from 7.0 to 4.0 leads to the decrease in LSCT of IPNs by up to 5 °C with respect to PNIPAM. By tuning the pH value to dissociate the formed inter-polymer hydrogen bonds, the formed IPNs would be able to fold cooperatively to a compact structure without a loss of solubility at temperatures below the LCST. Thus, these novel IPNs with AIE active moieties would be used as drug delivery systems, in which the release process could be readily monitored by fluorescence spectroscopy.

Graphical abstract: Aggregation induced emission based fluorescence pH and temperature sensors: probing polymer interactions in poly(N-isopropyl acrylamide-co-tetra(phenyl)ethene acrylate)/poly(methacrylic acid) interpenetrating polymer networks

Supplementary files

Article information

Article type
Paper
Submitted
17 Mar 2015
Accepted
27 Apr 2015
First published
27 Apr 2015

J. Mater. Chem. C, 2015,3, 5490-5498

Author version available

Aggregation induced emission based fluorescence pH and temperature sensors: probing polymer interactions in poly(N-isopropyl acrylamide-co-tetra(phenyl)ethene acrylate)/poly(methacrylic acid) interpenetrating polymer networks

H. Zhou, F. Liu, X. Wang, H. Yan, J. Song, Q. Ye, B. Z. Tang and J. Xu, J. Mater. Chem. C, 2015, 3, 5490 DOI: 10.1039/C5TC00752F

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements