Issue 6, 2019

Lyophilization of chemiluminescent substrate reagents for high-sensitive microchannel-based lateral flow assay (MLFA) in point-of-care (POC) diagnostic system

Abstract

Over the last few years, lateral flow assay (LFA) devices have grown to be the most common point-of-care test (POCT) platform facilitating disease diagnostics in low-resource environments. However, the lack of consistency and the limited sensitivity of these devices often lead to misdiagnosis and generates the need for an alternate approach. A chemiluminescence based microchannel-based lateral flow assay (MLFA) in a POCT platform can result in a much higher sensitivity but involves multiple additional steps of liquid reagents for the sequential execution of the signal amplification protocol. One of the best ways to develop a sample-to-answer system with minimum user intervention is to dry reagents on a chip prior to sample addition and to control the flow of the biological fluid through the drying chambers resulting in the reconstitution of the reagents. This work reports the methods for the successful lyophilization of the chemiluminescent substrate and its reconstitution in artificial serum without any significant loss of functionality. The lyophilized reagents were reconstituted and incorporated into the reaction chambers of a designed polymer lab-on-a-chip to implement a sandwich assay for the detection of malarial biomarkers. The results report a limit of detection (LOD) of 5.75 ng mL−1 which is sensitive enough to detect active malarial infection. Successful lyophilization and reconstitution of the chemiluminescent substrate, as reported here, can pave the way towards developing an autonomous POCT system implementing chemiluminescence based sandwich ELISA for enhanced sensitivity, portability, and ease-of-use in resource limited settings.

Graphical abstract: Lyophilization of chemiluminescent substrate reagents for high-sensitive microchannel-based lateral flow assay (MLFA) in point-of-care (POC) diagnostic system

Article information

Article type
Paper
Submitted
03 Oct 2018
Accepted
04 Jan 2019
First published
22 Jan 2019

Analyst, 2019,144, 2109-2119

Lyophilization of chemiluminescent substrate reagents for high-sensitive microchannel-based lateral flow assay (MLFA) in point-of-care (POC) diagnostic system

S. Ghosh and C. H. Ahn, Analyst, 2019, 144, 2109 DOI: 10.1039/C8AN01899E

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements