Issue 3, 2019

Understanding partial saturation in paper microfluidics enables alternative device architectures

Abstract

Paper-microfluidic devices are becoming more common due to their ability to automate diagnostic assays at low cost. Increasingly, paper-microfluidic devices automate more complex, multi-step assays, with the aim of bringing these assays out of the laboratory to the point-of-care. However, some common assay procedures have resisted easy automation by paper-microfluidic devices. Sample preparation procedures in particular, due to the complexity of real biological samples, still largely involve the manual execution of multiple user steps before addition to a paper device, often with the aid of specialized equipment. In the laboratory, most sample types are exposed to (bio)chemical treatment to release target species, which often requires additional purification steps prior to detection. Some samples, such as urine, also require concentration of target species; others, such as nasal swabs or blood, also require removal or dilution of non-target species that interfere with downstream assay steps. Additionally, the samples used in many laboratory assays require volumes (milliliter scale) too large to process efficiently with paper devices. To broaden the effectiveness and availability of point-of-care testing, we have developed and characterized a technique that automates either the concentration or dilution of large-volume samples in paper-microfluidic devices. Here we demonstrate its simplicity and broad utility in two ways: (1) an automated parallel dilution system for an immunoassay detection antibody and (2) an automated DNA extraction and concentration system for mL-sized samples. This and similar techniques rely on an improved understanding of how fluids wet porous materials and flow through multi-material networks; they confer important new capabilities to paper-microfluidic devices, the most important of which is the integration of complex sample preparation with downstream biomolecule detection.

Graphical abstract: Understanding partial saturation in paper microfluidics enables alternative device architectures

Supplementary files

Article information

Article type
Paper
Submitted
10 Sep 2018
Accepted
04 Dec 2018
First published
14 Dec 2018

Anal. Methods, 2019,11, 336-345

Author version available

Understanding partial saturation in paper microfluidics enables alternative device architectures

J. R. Buser, S. A. Byrnes, C. E. Anderson, A. J. Howell, P. C. Kauffman, J. D. Bishop, M. H. Wheeler, S. Kumar and P. Yager, Anal. Methods, 2019, 11, 336 DOI: 10.1039/C8AY01977K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements