Issue 2, 2021

Duplex-specific nuclease signal amplification-based fluorescent lateral flow assay for the point-of-care detection of microRNAs

Abstract

MiRNAs play important regulatory roles in numerous biological processes and serve as significant biomarkers for the development and prognosis of several diseases. Their unique characteristics, such as short size, high sequence homology among family members, low abundance, and easy degradability, have hindered their specific and highly sensitive detection. Herein, a duplex-specific nuclease (DSN)-assisted target recycling signal amplification-based fluorescent lateral flow assay was demonstrated for the point-of-care detection of cancer-related miRNA-21. In this assay, digoxin/biotin-labeled DNA probes were selectively cleaved by the DSN enzyme in the rounds of hybridization with the miRNA-21 target and cleavage cycle. Subsequently, the resulting mixture, containing the miRNA-21 target and intact and cleaved DNA probes, was loaded onto the lateral flow strip with digoxin antibody-conjugated quantum dot nanobeads and the streptavidin-coated test line. The increase in the proportion of cleaved DNA probes can induce a weakened response signal, which is directly associated with the amount of the miRNA target. Thus, highly sensitive quantification of miRNA-21 was achieved at a low limit of detection of 0.16 pM within 2 h of assay time. Assay specificity toward miRNA-21 was validated by testing several other miRNAs, including let-7b, let-7d, miRNA-141, and miRNA-200a. Moreover, the assay can quantify miRNA-21 spiked in human serum samples with acceptable recovery values, thus indicating its considerable clinical feasibility.

Graphical abstract: Duplex-specific nuclease signal amplification-based fluorescent lateral flow assay for the point-of-care detection of microRNAs

Supplementary files

Article information

Article type
Paper
Submitted
18 Aug 2020
Accepted
21 Oct 2020
First published
23 Oct 2020

Analyst, 2021,146, 558-564

Duplex-specific nuclease signal amplification-based fluorescent lateral flow assay for the point-of-care detection of microRNAs

H. Wei, Y. Peng, Z. Bai, Z. Rong and S. Wang, Analyst, 2021, 146, 558 DOI: 10.1039/D0AN01673J

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements